Ecler TP-NET Manuale Utente Pagina 9

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 35
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 8
9
OVU <Output Channel> <Pre Vumeter Level> <Post Vumeter Level> Shows the VU-meter value of an
Output Channel
ALARM_PROTECT <Output Channel> ON/OFF Shows the Protect alarm status of an
Output Channel
ALARM_FAULT <Output Channel> ON/OFF Shows the self-diagnosis system alarm
status of an Output Channel
INFO_NAME “<Device Name>” Shows the Device Name
INFO_MODEL <Device Model> Shows the Device Model
INFO_VERSION <Firmware Version> Shows the Firmware Version
INFO_MAC <Device MAC
address>
Shows the Device MAC address
ERROR
<Error ID> “<Error Description>” Informs about an error
Note: INC and DEC commands are replied with a DATA command from the device with the resulting LEVEL value, after it has been increased or decreased.
When the INC or DEC command tries to adjust a LEVEL value beyond its minimum or maximum limits, no reply (DATA command) will be produced.